Strudyna Balcony System

Page 1

BALCONY system system

316 Stainless Steel Modular Balcony System

SBS V2.0


1100

Sketch elevation front ront vie view ew

3D Model

2400

Plan view

BALCONY system

A

Balcony system A was designed for buildings which have a one side open balcony or a corner balcony. The system is very suitable for apartments and condominiums where there is a requirement for the balustrade to look modern & striking. Using wire infill for the balustrade balcony system, alongside stainless steel balusters, adds transparency, increasing the available view whilst remaining very safe for high floor balconies. System A also uses a continuous handrail, increasing aesthetic appeal and safety for the dwelling owner. The system is incredibly strong, safe & easy to install and because all of the component parts are made form 316 Stainless steel, the system will endure any weather for many years.

Balcony system A 3D Model Assembly parts for Balcony system A for 1 set NO.

2

4.1 4.2 6

5 9

7 3.1

3.2

8

1

Name

Code

Size

1. Stanchion base

BC1B-1008

51mm*90mm*85mm

3 PCS

2. Stanchion angle

BC3H-0038

38mm*77mm*40mm

8 PCS

3.1 Stanchion post type A (Middle) BC1P-MD90

40mm*9mm*874mm

1 PCS

3.2 Stanchion post type B (End)

40mm*9mm*874mm

2 PCS

BC2P-EN90

4.1 Flat bar handrail type A1

BC5H-6508-2370 50.8mm*9mm*2370.4mm 1 PCS

4.2 Flat bar handrail type A2

BC6H-6508-1014 50.8mm*9mm*1014.6mm 1 PCS

5. Link adjuster

BC1A-1208

12mm*77mm

8 PCS

6. Cover plate

BC1C-2803

28mm*3mm

8 PCS

7. Link plate

BC2H-0090

50mm*3mm*90mm

1 PCS

8. EM6 Deco stud

2960-3630

3mm M6*30mm

16 PCS

CX19-0003-1597

3mm*1597mm

8 PCS

9. Cable 1x19

Accessories - Flat head socket cap screw - Screw - Stud anchor - Adhesive capsule anchor (HVU) - Threaded stud - Domed nut - Washer - Right thread nut - Stanchion bush

www. strudyna.com

for 1 set

6799-1815 6933-0825 PBH2-6880 PBH3-0880 2955-0830 6158-7610 6158-7812 6914-1381 2000-2206 BC2B-0006

M8*1.25*20mm M8*25mm M8*80mm M8*80mm M8 M6 M8 1.5mm*8.5mm*18mm 6mm 14.28mm*6mm

18 12 16 16 2 16 26 26 16 6

PCS PCS PCS PCS PCS PCS PCS PCS PCS PCS

page 2


1100 2400

3DModel Model 3D

SSketch elevation front view w

Plan view

BALCONY system

Balcony system B 3D Model

B

B Ba Balcony alc lcon lcon onyy System Syst Sy stem tem B h has as b been bee een ee n designed desi de sign ign g ed d for for apartme apartments ents and condominiums with a narrow balcony, side. Because the application which iss open on just one side is for single sided balconies and incorporates wire infill, system B is very elegant with maximum transparency. Wire infill and steel balusters allow for a panoramic view from the balcony, barely obscuring views for its owners. Furthermore, for warmer countries, the lack of a paneled balustrade structure, e.g., Glass means that wind and fresh air are able to circulate freely. This system is a viable alternative to paneled systems, potentially adding value to any apartment or condo because of increased aesthetic and functional advantages over paneled systems. System B can be easily installed and again, because of the use of 316 Stainless in all components, the system has a high resistance to corrosive environmental circumstances that might leave other systems tarnished, or worse still in need of repair.

Assembly parts for Balcony system B for 1 set NO.

2

4

5

2

7 6

Code

Size

for 1 set

1. Stanchion base

Name

BC1B-1008

51mm*90mm*85mm

3 PCS

2 Stanchion angle

BC3H-0038

38mm*77mm*40mm

8 PCS

3.1 Stanchion post type A (Middle)

BC1P-MD90

40mm*9mm*874mm

1 PCS

3.2 Stanchion post type B (End)

BC2P-EN90

40mm*9mm*874mm

2 PCS

4 Flat bar handrail type B

8

3.1

3.2

BC1H-6508-2290 50.8mm*9mm*2290mm 1 PCS

5 Link adjuster

BC1A-1208

12mm*77mm

4 PCS

6 Cover plate

BC1C-2803

28mm*3mm

4 PCS

7 EM6 Deco stud

2960-3630

3mm M6*30mm

16 PCS

CX19-0003-2108

3mm*2108mm

8 PCS

6799-1815 6933-0825 PBH2-6880 PBH3-0880 2955-0830 6158-7610 6158-7812 6914-1381 2000-2206 BC2B-0006

M8*1.25*20mm M8*25mm M8*80mm M8*80mm M8 M6 M8 1.5mm*8.5mm*18mm 6mm 14.28mm*6mm

12 PCS 12 PCS 12 PCS 12 PCS 2 PCS 16 PCS 24 PCS 24 PCS 16 PCS page 6 PCS

8 Cable 1x19

1

Accessories - Flat head socket cap screw - Screw - Stud anchor - Adhesive capsule anchor (HVU) - Threaded stud - Domed nut - Washer - Right thread nut - Stanchion bush

www. strudyna.com

page 3


700

2000

Plan view

3D Model Model 3D

Sketch elevation front view

BALCONY system

C

Balcony System C has been designed for apartments and condominiums with larger balcony alcony areas. In particular, its most suitable for long terraces and those built with corners. This system has real functional & aesthetic etic appeal due to the continuous wires which run n the entire length of the balcony perimeter. Because se of the use of wire infill as opposed to paneled sections, ectionss, balcony system C helps the terrace look and feel very open, promoting panoramic views and a feeling g of increased space. In warmer climates, the wire infill also aids the movement of air throughoutt the area, supporting a relaxing balcony / terrace environment. Balcony system C continues to champion on the trend for transparency, safety and functionality ty whilst remaining easy to install and weather resistant. Like Lik all of the Strudyna balcony systems, the use of 316 stainless steel in the system component means that the system will continue to look great and perform its primary functions for many years, with little maintenance required.

Balcony system C 3D Model Assembly parts for Balcony system C for 1 set NO.

Name

Code

Size

1. Stanchion base

BC1B-1008

51mm*90mm*85mm

8 PCS

2.1 Stanchion angle 2.2 Stanchion angle link

BC3H-0038

38mm*77mm*40mm

16 PCS

3.1 Stanchion post type A (Middle)

BC1P-MD90

40mm*9mm*874mm

2 PCS

3.2 Stanchion post type B (End)

BC2P-EN90

40mm*9mm*874mm

6 PCS

4.1 Flat bar handrail type C1

4.3. 2.1. 4.2. 5

6

3.2.

2.2

3.1. 9.1

8 1

4.2 Flat bar handrail type C2

BC8H-6508-2564 50.8mm*9mm*2564.1mm 1 PCS

4.3 Flat bar handrail type C2

BC8H-6508-A564 50.8mm*9mm*564.1mm 1 PCS

5. Link adjuster

BC1A-1208

6. Cover plate 7. Link angle 90 degree

7

9.2

4 PCS

BC1C-2803

28mm*3mm

4 PCS

BC2A-1208

12mm*95.5mm

6 PCS

2960-3630

3mm M6*30mm

48 PCS

3mm*2392 mm

8 PCS

9.2 Cable 1x19

CX19-0003-1577

3mm*1577 mm

8 PCS

9.3 Cable 1x19

CX19-0003-0392

3mm*392 mm

8 PCS

Accessories - Flat head socket cap screw - Screw - Stud anchor - Adhesive capsule anchor (HVU) - Threaded stud - Domed nut - Washer - Right thread nut - Stanchion bush

www. strudyna.com

12mm*77mm

CX19-0003-2392

9.1 Cable 1x19

4.1.

113.5mm*77mm*40mm 2 PCS

BC7H-6508-1850 50.8mm*9mm*1850.8mm 1 PCS

8. EM6 Deco stud

9.3 2.1.

BC4H-J113

for 1 set

6799-1815 6933-0825 PBH2-6880 PBH3-0880 2955-0830 6158-7610 6158-7812 6914-1381 2000-2206 BC2B-0006

M8*1.25*20mm M8*25mm M8*80mm M8*80mm M8 M6 M8 1.5mm*8.5mm*18mm 6mm 14.28mm*6mm

36 32 22 22 2 48 72 56 48 16

PCS PCS PCS PCS PCS PCS PCS PCS PCS PCS

page 4


15.6 M.

4 M.

Plan view

Sketch elevation right side view 4.8 M.

3D Model

BALCONY system

D Balcony system D 3D Model

Balcony System D was developed for use in public areas, helping to create a modern visually appealing system that also compliments any existing building infrastructure. For use indoor or outside in public areas, Strudyna Balcony System D continues to promote maximum transparency, a departure from traditional paneled or solid balustrade which can restrict view’s and the movement of air. System D, like the systems detailed previously in this brochure, is very strong and safe with a tensioned wire infill. Wire infill promotes transparency and unrestricted views beyond any perimeter. In warmer countries, the wire infill also helps aid the movement of air in any space, helping to keep the environment cool and relaxing. Made with 316 stainless steel components, balcony system D is incredibly strong & corrosion resistant; the system is also very easy to install and maintain. These features arevery desirable in public areas, especially if the balustrade is very large as this equals a significant saving in terms of installation and ongoing operational expenditure. The system will continue to look great and last for years even in harsh environmental circumstances.

Assembly parts for Balcony system D (Commercial) No.

Name

Strudyna Balcony system D (Commercial)

Code

Size

Name

1. Stanchion base (Flexible)

BC3B-0008

50mm*100mm*90mm

Accessories

2.1 Stanchion angle 2.2 Stanchion angle link

BC3H-0038

38mm*77mm*40mm

BC4H-J143

143.5mm*77mm*40mm

Code

Size

- Flat head socket cap screw

6799-1815

M8*1.25*20mm

- Screw

6933-0825

M8*25mm

6933-0830

M8*30mm

3.1 Stanchion post type A (Middle)

BC1P-MD11

40mm*9mm*1074mm

3.2 Stanchion post type B (End)

BC2P-EN11

40mm*9mm*1074mm

- Stud anchor

PBH2-6880

M8*80mm

- Adhesive capsule anchor (HVU) PBH3-0880 - Threaded stud 2955-0830 - Domed nut 6158-7610

M8*80mm

4. Flat bar handrail type D

Contact sale team

50.8mm*9mm*xxxxmm

5. Link adjuster

BC1A-1208

12mm*77mm

6. Cover plate

BC1C-2803

28mm*3mm

7. Link angle 90 degree

BC2A-0C08

12mm*131.5mm

8. Link for double stanchion post

BC3A-1208

12mm*30mm

9. EM6 Deco stud

2960-3630

3mm M6*30 mm

CX19-0003-xxxx

3mm*xxxx mm

10. Cable 1x19

www. strudyna.com

M8 M6 M8

6158-7812

- Washer

6914-1381 1.5mm*8.5mm*18mm

- Right thread nut

2000-2206

6mm

*See more assembly parts details at page 13-16

page 54


A guide to specifying Strudyna Balcony Systems

A

Step 1

Step 2 Rule ule

Select the type of Strudyna Balcony System which is most suitable for your terrace or balcony.

Picture 1

Refer to the criteria laid out in the standard IBC of America for the conditions governing balcony design and installation. These conditions and recommendations have been summarized below.

The condition of balcony installation

243

1) Function : (See picture no.1) The balcony is appropriate with the private area and the public area; e.g. building, apartment or condominium. The height of balcony is specified as following this. Private area Private area 1.1 The private area should apply to the height of balcony at 900 mm. H 900 mm. H 1,100 mm. 1.2 The public area should apply to the height of balcony at 1100 mm. 2) The strength of the pole: (See the picture no.2) 2.1 The force all directions at 0.85 kN/m (product is not damage.) Picture 2 2.2 The pressure strength of cable at 0.22 kN/m (cable is not broken.) 3) The gap: (See the picture no.3) 3.1 The gap between the cable; the width should not be over 102 mm. (our product has the gap at 100 mm.) 3.2 The gap between the poles should not be over 1200 mm. If it is over 1200 mm, it should have the pole at the centre. 4) The size of handrails: The handrails as round type, the diameter should be 35-40 mm. For the other handrails should measure the perimeter between 102-160 mm. 5) The quantity of connector for the pole and wall For 5.1 Link adjuster used for connecting between pole and wall ce A ll di - Height of the pole 900mm use 2 pcs - Height of the pole 1,100mm use 3 pcs rect ions 5.2 Link angle 90 degree connect at the angle of the pole 0.89 - Height of the pole 900mm use 3 pcs - Height of the pole 1,100mm use 5 pcs kN/ m. 6) The point of angle for the top handrail has to use the connector every points: (See the picture no.5) 6.1 The balcony type A use the Link plate for connecting. All gap = 100 mm. 6.2 The balcony type B use the Stanchion angle link L shape for connecting. 7) Stainless steel anchor: (See picture no.6) 7.1 Use Chemical anchor- the length from the edge of cement to the drilling hole is between 50-80mm. 7.2 Use Metal anchor – the length from the edge of the cement to the drilling hole 80mm up. 8) Cable fitting (EM6): (See picture no.4) 8.1 Use with the cable 1x19. 8.2 Cable dia 3.4mm .(for the mock up sample we use cable dia 3mm) 8.3 The length of cable 3.4mm dia.per piece is not over 2400mm. 8.4 The height of balcony 900mm, use the cable 8 pcs. 8.5 The height of balcony 1100mm, use the cable 10 pcs. 9) The whole structure: ( Balcony system type A, B, C & D ) 9.1 All the parts with the thread, the thread have to be right hand thread. Picture 3 9.2 Balcony system use the thread M6 and M8 only. 9.3 All the parts with the thread M6, there are used for assembly with cable fittings only.

Link Plate

Min 50 mm. Stanchion Angle Link

Mi

n5

Picture 4

www. strudyna.com

Picture 5

Picture 6

0m

m.

page 6


Assembly & Installation Procedures for Strudyna Balcony Systems. Ho How ow w tto o

Step 3

Study the installation guide and follow the installation steps detailed over the following pages.

Step 4

Contact the Strudyna Sales team if you require further information regarding our proprietary Balcony Systems and their installation or if you are interested in additional products, services and capability available from Strudyna.

1. Prepare all components and tools See more information on page 15-16

Nuts & Bolts

Tools A Balco

A stem ny sy

1

1 2

3

4

5

2

6

7

3

8

9

4

10

BT933

BT7991

Hex wrench/Spanner

PBH2

BNUT/DIN1587

BC3B

BFWA/E1

BC2B

BC3H

BC4H (Link)

1100

900

BC1H, BC5H, BC6H BC7H, BC8H

www. strudyna.com

BC2A

SFNUT/R

For more information please see pages 13-15

Stanchion Post Components

BC1A

PBH3

Electric drill

6, 10, 13

BC1B

PBH1

BC1P, BC2P

BC3A

BC2H

BC1C

page 7


Assembly Procedure for Strudyna Balcony Systems A, B, C & D 2. Once you have organized your balcony system components, carefully follow the installation guide as laid out below and in the following pages.

Assemble each post as per the below diagrams

Post Balcony Type A,B,C (Residential) 900 mm. Type 1

Type 2

Type 3

End post

Middle post

Corner post

Type 4

Handrail with link adjuster

Type 5 Link plate detail

Type 6 Angled connection for handrail to wall

Post Balcony Type D (Commercial) 1100 mm. Type 1

Type 2

End post

Middle post

Type 3 Double post

Type 4 Corner post

Type 5 Angled connection for handrail to wall

*Recommended to use Type 3 double post for every 2400 mm. (refer to the length of cable per piece is not over 2400 mm)

www. strudyna.com

page 8


The Installation Procedures for Strudyna Balcony Systems A, B & C (Residential) Assemble each post as per the below diagrams. 9.

13 9.

13

14.

3.1 14. 13

3.1 14.

13

9.

13

13 3.1

3.2

14.

10.

14.

10.

14. 13

13

14.

10. 2.2

9.

9.

2.1

8. 2.2

2.2

11 6.

9.

7.

13

13

13

15. 10.

15.

15 10

13

13

13

10. 1.

1.

End post Type 1

11

Middle post Type 2

4.1

9.

Corner post Type 3

NO.

Name

Code

Size

BC1B-1008

51mm*90mm*85mm

2.1 Stanchion post type A (Middle) BC1P-MD90

40mm*9mm*874mm

2.2 Stanchion post type B (End)

BC2P-EN90

40mm*9mm*874mm

3.1 Stanchion angle

BC3H-0038

38mm*77mm*40mm

3.2 Stanchion angle link

BC4H-J113

113.5mm*77mm*40mm

Component 1. Stanchion base

7. 6. 11 Handrail with link adjuster Type 4

12.

9.

4.1

7. 6.

4.1 Flat bar handrail type A1

BC5H-6508-XXXX 50.8mm*9mm*XXXXmm

4.2 Flat bar handrail type A2

BC5H-6508-XXXX 50.8mm*9mm*XXXXmm

5. Link plate

BC2H-0090

50mm*3mm*90mm

6. Cover plate

BC1C-2803

28mm*3mm

7. Link adjuster

BC1A-1208

12mm*77mm

8. Link angle 90 degree

BC2A-1208

12mm*95.5mm

Accessories 9. Flat head socket cap screw

6799-1815

M8*1.25*20mm

6933-0825

M8*25mm

PBH2-6880 Adhesive capsule anchor (HVU) PBH3-0880

M8*80mm M8*80mm

10. Screw

4.2

5.

11. Stud anchor

Use with Stud anchor

Angled connection for handrail to wall Type 6

www. strudyna.com

11

11

11

12. Threaded stud 13. Dome nut Link plate Detail Type 5

1.

1.

14. Washer 15. Stanchion bush

PBH2-6880

2955-0830

M8*30mm

6158-7812

M8

6914-1381

1.5mm*8.5mm*18mm

BC2B-0006

14.28mm*6mm

page 9


Assembly Guide for Balcony System D (Commercial) Assembly each post as below

3.1

3.1

8.

7

8. 3.1

8. 12.

12. 12.

9.1

11.

9.1 12.

12.

9.1 11. 12.

2.2

10

2.2

2.1

8.

4. 5.

8.

9.2

9.2 9.2

1.

1.

12. 11.

11. 1. 12.

10.

10. Middle post Type 2

11.

10.

End post Type 1

11.

Double post Type 3

8.

3.1 NO.

3.2

Name

Code

Size

BC3B-0008

50mm*100mm*90mm

2.1 Stanchion post type A (Middle) BC1P-MD11

40mm*9mm*1,074mm

2.2 Stanchion post type B (End)

BC2P-EN11

40mm*9mm*1,074mm

3.1 Stanchion angle

BC3H-0038

38mm*77mm*40mm

3.2 Stanchion angle link

BC4H-J143

143.5mm*77mm*40mm

4. Cover plate

BC1C-2803

28mm*3mm

5. Link adjuster

BC1A-1208

12mm*77mm

Component

1. Stanchion base (Flexible)

9.1

12. 11.

8.

6. 2.2

9.2

BC2A-1208 6. Link angle 90 degree 7. Link for double stanchion post BC3A-1208 Accessories 8. Flat head socket cap screw 9.1 Screw

10.

12. Corner post Type 4

www. strudyna.com

1.

12mm*30mm

6799-1815

M8*1.25*20mm

6933-0825

M8*25mm

6933-0830 PBH2-6880 Adhesive capsule anchor (HVU) PBH3-0880 Use with Stud anchor PBH2-6880

M8*30mm M8*80mm M8*80mm

9.2 10. Stud anchor 11.

12mm*131.5mm

11. Dome nut

6158-7812

M8

12. Washer

6914-1381

1.5mm*8.5mm*18mm

page 10


Installation Guide for Strudyna Balcony System A, B & C (Residential) Tip For accurate installation, follow these 6 simple steps.

Min 50 mm.

Ă˜ 8 mm

1.

2.

4.

3.

6.

243

5.

9m

243

Tip Use Loctite for safety.

243

m.

9m

m.

www. strudyna.com

page 11


Installation Guide for Strudyna Balcony System D (Commercial) Tip For accurate installation, follow these 6 simple steps.

Ă˜ 8 mm Min 100 cm.

1.

2.

4.

3.

6.

243

5.

9m

243

Tip Use Loctite for Safety

243

m.

9m

m.

www. strudyna.com

page 12


Stanchion post Order no.

BC1B

Item

A (mm)

B (mm)

H (mm)

L1 (mm)

T (mm)

BC1B-1008

51

30

85

90

8

Order no. Item

A (mm)

B (mm)

H (mm)

L1 (mm)

T (mm)

BC3B-0008

50

30

90

100

10

BH

T

A

Stanchion base Technical Data Casting material : AISI316 - DIN 1.4408 Surface treatment : "M.F." (Matte finished) TAP : N/A

L1

B

BC3B

H T A

Stanchion base Technical Data Casting material : AISI316 - DIN 1.4408 Surface treatment : "M.F." (Matte finished) TAP : N/A

L1

Item

A (mm)

B (mm)

L (mm)

T (mm)

BC3H-0038

40

77

38

3

BC4H-J113

40

77

113.5

3

BC4H-J143

40

77

143.5

3

Order no. L

BC4H (Link)

L T

BC3H Stanchion angle

B

Technical Data Sheet material : AISI316L - DIN 1.4408 Surface treatment : "M.F." (Matte finished) TAP : N/A

A ØD

BC1P

ØD1

L1

L1

BC2P

A

BC1P

BC2P

type A (Middle) e)

type B (End)

L T

Order no.

A (mm)

ØD (mm)

ØD1 (mm)

L (mm)

L1 (mm)

T (mm)

BC1P-MD90

40

9

6.9

874

30

9

BC1P-MD11

40

9

6.9

1074

30

9

BC2P-EN90

40

9

6.9

874

30

9

BC2P-EN11

40

9

6.9

1074

30

9

Item

Stanchion post ost Technical Data Flat bar material : AISI316 Surface treatment : "M.F. " (Matte finished) TAP

: N/A

www. strudyna.com

page 13


Flat bar handrail A

BC1H, H, BC5H, BC6H BC7H, H, BC8H

L T For System A

Flat bar handrail Technical Data Sheet material : AISI316 Surface treatment : "M.F. " (Matte finished) TAP : N/A

Item

A (mm)

L (mm)

T (mm)

A1

BC5H-6508-XXXX

50.8

select

9

A2

BC6H-6508-XXXX

50.8

select

9

B

BC1H-6508-XXXX

50.8

select

9 9 9

B C

Order no.

Type

C1

BC7H-6508-XXXX

50.8

select

C2

BC8H-6508-XXXX

50.8

select

* Contact to Strudyna Sale team for checking the length and hole * Contact to Strudyna Sale team for more information of system D

Connector M

BC1A

Order no. L

ØD

Item

ØD (mm)

M (thread)

L (mm)

BC1A-1208

12

M8

77

Order no. Item

ØD (mm)

ØD1 (mm)

T (mm)

BC1C-2803

28

9

3

Order no. Item

A (mm)

L (mm)

T (mm)

BC2H-0090

40

50

3

Order no. Item

ØD (mm)

L (mm)

M (thread)

BC2A-1208

12

95.5

M8

BC2A-0C08

12

131.5

M8

Order no. Item

ØD (mm)

L (mm)

M (thread)

BC3A-1208

12

30

M8

Link adjuster Technical Data

ØD1

Bar material : AISI316 Surface treatment : "M.F. " (Matte finished) TAP : N/A

BC1C

Cover plate Technical Data Sheet material : AISI316L Surface treatment : "M.F. " (Matte finished) TAP : N/A

ØD

T

BC2H A

Link plate

T

L

Technical Data Sheet material : AISI316L Surface treatment : "M.F. " (Matte finished) TAP : N/A

L M

BC2A

Link angle 90 degree Technical Data Bar material : AISI316L I316L Surface treatment : "M "M.F. F " (Ma (Matte finished) TAP : N/A

ØD

BC3A ØD

Link for double ble stanchion post Technical Data Threaded stud

: Bar Forging material AISI316, EN 1.4401 Surface treatment : Matt finished TAP : N/A TAP

: 27.1

www. strudyna.com

L

M

page 14


Cable Fitting SF960

Order no.

ØOD

M

Item

L1 L

2960-3630

Ø Cable L (mm) (mm)

3

L1 (mm)

30

M ØOD (thread) (mm)

12

M6

6.35

EM6 deco stud cable Technical Data Bar material : AISI316L Surface treatment : "M.F. " (Matte finished) TAP : 57.10

ØD

CX19

LOC2

L

Hamma X 1x19

Loctite 263

Technical Data Cable material : AISI316 Construction : Spiral strand Configuration : 1x19 = 1+6+12 Module of elasticity : 132 +/-10 kN/mm Note : Limit tension is calculated at 60% of MBL.

Order no. Item

Size

Order no.

Size

LOC2 - 6350

50 ml.

Ø Size Cable Lenght Limit Tension (mm) (mm) (kN)

Length

CX19-0003-0000

3

4.45

select

Nuts & Bolts BT7991

Order no.

M

L

Flat head socket cap screw

Item

ØD (mm)

L (mm)

M (thread)

6799-1815

16

20

M8

Order no. Item

ØD (mm)

L (mm)

M (thread)

6933-0825

13

25

M8

6933-0830

13

30

M8

ØD

Technical Data Material

: AISI316 - DIN 7991

BT933 M L

Screw

ØD

Technical Data Material : AISI316 - DIN 933

M

PBH1

Order no.

L

PBH2

M

Stud anchor

L

Technical Data Material : AISI316 - DIN 1.4401

M (thread)

L (mm)

PBH1-6875

M8

75

PBH2-6880

M8

106

PBH3-0880

Adhesive capsule for stud anchor

PBH2-6880

PBH3 Order no.

ØM

SF955

Item

L

Item

M (thread)

L (mm)

2955-0830

M8

30

Threaded ded stud Technical Data Threaded stud tud

: Bar Forging material AISI316, EN 1.4401 Surface treatment : Matt finished TAP : N/A

M

Order no.

BNUT/DIN1587 L

Dome nut

L (mm)

M (thread)

S.W. (mm)

6158-7610

12

M6

10

6158-7812

15

M8

12.8

Item

S.W.

Technical Data Material : AISI316 - DIN 1587 TAP

: 27.1

www. strudyna.com

page 15


ACCESSORIES Nuts & Bolts BFWA/E1

Order no.

T

ØD1 ØD

Washer

Item

ØD (mm)

ØD1 (mm)

T (mm)

6914-1381

18

8.5

1.5

Order no. Item

ØD (mm)

ØD1 (mm)

T (mm)

BC2B-0006

14.28

8.45

6

Order no. Item

M (thread)

T (mm)

S.W. (mm)

2000-2206

M6

5

10

Technical Data Sheet material : AISI316 Surface treatment : "E.P." (Electro polished)

BC2B

Stanchion bush

ØD1 ØD

Technical Data

T

Bar material : AISI316 Surface treatment : Machine finished

M

SFNUT/R Right thread nut

S.W.

T

Technical Data Bar material : AISI316 Surface treatment : "E.P. " (Electro polished) Bar material : AISI316

MOCK UP BALCONY

Stainless steel 316 grade

Exclusive Agents Year 2014

Structural Dynamics Australia 4 / 14 Dover Drive Burleigh Heads Queensland 4220 Australia Tel : +07 5568 7084 Fax : +07 5576 5166 Email : ross@strudyna.com.au

www. strudyna.com

Structural Dynamics Europe Limited. Unit 10 Wingate Rd. Gosport, Hampshire, UK. PO12 4DP Tel : +44 (0) 845 262 5557 Fax : +44 (0) 239 294 0272 Email : sales@strudyna.eu

Anzor Fasteners Ltd. 8 Arrenway Drive Albany, Auckland, New Zealand Tel : +(64) 9 476 0001 Fax : +(64) 9 476 0090 Email : sales@anzor.co.nz

www. strudyna.com

Keng Wah Hardware Co. Pte. Ltd. Blk 2 Kitchener Road #01-85 Singapore 200002 Tel : +(65) 6392 4896 Fax : +(65) 6296 4736 Email : sales@kengwah.com

page 16


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.