Model kde

Page 1

MODEL KDE

Aluminum Square Diffusers

Application • Versatile Supply Air Diffuser for constant or variable air volume cooling , heating or ventilating • Directional diffusers are offered in all standard square dimensions with a variety of cores to provide any required air pattern. • Directed air diffusion for space coverage with great flexibility in space layout and geometry, and diffuser location • Surface mounted

Product Features • Core is removable to facilitate access to duct / damper • KDE Series feature a square neck • Concealed core attachment – NO screws • Powder coated – RAL 9010 finish

Construction • Available in wide variety of standard neck sizes ranging from 150mm x 150mm up to 600mm x 600 mm, available in 75 mm increments. • The core is held in place & fixed to the frame by two loaded spiral galvanized steel springs. • Foam gasket is sealed around the back of the frame as option to avoid air leakage Model KDE – Surface Mounted

Dimensional Data Nominal Neck Size

Actual Neck Size

Outer Frame Size

mm

inch

mm

mm

False Ceiling Opening Size mm

150 x 150

6”x 6”

135 x 135

297x 297

233 x 233

225 x 225

9”x 9”

210 x 210

372 x 372

308 x 308

300 x 300

12”x 12”

285 x 285

447 x 447

383 x 383

375 x 375

15”x 15”

360 x 360

522 x 522

458 x 458

450 x 450

18”x 18”

435 x 435

597 x 597

533 x 533

525 x 525

21”x 21”

510 x 510

672 x 672

608 x 608

600 x 600

24”x 24”

585 x 585

747 x 747

683 x 683

PRODUCT SELECTION CHECK LIST • Select Unit Size based on desired performance characteristics • Select blade orientation • Select finish

www.kmcqatar.com

1


MODEL KDE

Aluminum Square Diffusers Performance Data

Notes : Standard ANSI / ASHRAE standard 70

Pressure Pt represents Total Pressure, Pascal (Pa), measured in the supply duct

Sound Levels NC is noise criteria curve that will not be exceeded at the operating point for thesupply air volume shown. This is determined by assuming a 10dB(ref: 1012 watts) room attenuation that is subtracted from the power levels ineach of the 2nd thru 7th octave bands Return Use: Add + 2 to the NC shown in the tables

Neck Velocity Meters per second (m/s), measured in the supply duct

Throw The numbers shown are throw distances, in meters, measured along the jettrajectory axis relating to terminal velocities of 0.75, 0.5 &0.25 m/s with the jetattached to the ceiling surface.

2

www.kmcqatar.com