New Jersey Lab Certification for Water Quality Instruments Qualifications Statement

Page 1

NEW JERSEY LAB

CERTIFICATION FOR WATER QUALITY INSTRUMENTS

QUALIFICATIONS STATEMENT

20 24
FIELD ENVIRONMENTAL INSTRUMENTS

PURPOSE

New Jersey Administrative Code 7:18

In the state of New Jersey:

“N.J.A.C. 7:18 requires that any environmental laboratory submitting analytical data to the Department, regardless of quality level, must be certified by the Office of Quality Assurance. This applies to those firms using LFPS instruments associated with the “analyze immediately” category of water quality indicator parameters (WQIPs) including pH, temperature, and dissolved oxygen. Regardless of whether or not the equipment in question is rented or privately owned the requirement for certification can not be ignored.”

The New Jersey Department of Environmental Protection Office of Quality Assurance issued lab # PA096 to the Philadelphia Branch location of Field Environmental Instruments, Inc., (FEI) to provide certified water quality instruments after FEI met the appropriate testing & record keeping standards

2
Aquaread AP 800

FEI ADVANTAGE

What FEI Provides so customers are N.J.A.C. Compliant

• N.J.A.C. certified water quality instruments available for rental within method number and parameter:

– Specific Conductance Method: SM 2510 B-11

– Turbidity Method: SM 2130 B-11

– Dissolved Oxygen Method: SM 4500-O G-18

– pH Method: SM 4500-H B-11

– Temperature Method: SM 2550 B-11

• Calibration sheets for each piece of equipment

• Unit history and maintenance logs

• Technical assistance with New Jersey Labs procedures

• Ease with swapping out equipment to stay in compliance

3

AquaRead Calibration Certificate

*Solutions

All

4 Cal Standard Lot # Expiration Pre-Cal Reading Post-Cal Reading Acceptable Range PH 7 @ 25°C 6312007 12/18/2025 7.09 7.00 (6.86 to 7.14) pH mV value 25.5 (0 mV +/- 50mV) Cal Standard Lot # Expiration Pre-Cal Reading Post-Cal Reading Acceptable Range PH 4 @ 25°C 6308004 8/22/2025 4.09 4.01 (3.92 to 4.08) PH Slope (mV) 56.50 > 45 mV Cal Standard Lot # Expiration Pre-Cal Reading Post-Cal Reading Acceptable Range PH 10 @ 25°C 6312010 12/18/2025 10.06 10.00 (9.80 to 10.20) PH Slope (mV) 57.60 > 45 mV Cal Standard Lot # Expiration Pre-Cal Reading Post-Cal Reading Acceptable Range Conductivity 8310609 11/14/2025 1584.000 1.409 (1.338 to 1.479) Dissolved Oxygen Pre-Cal Reading Post-Cal Reading 100% Saturation Check Standard ORP Turbidity 0 NTU 1000 NTU Model Cable Length Sonde SN 105990440 Handheld SN 102392927 Barcode U94345X Order # 547279
provided by LabChem (412-826-5230)
calibration solutions used are traceable
NIST. Additional documentation is available
request. CALIBRATION DOCUMENTATION Calibration and Unit History Documents Sent with Order
calibrations performed by FEI conform to manufacturer's specifications. Please report any issues within 24 All
to
upon

CERTIFIED WATER QUALITY INSTRUMENTS

Multi-Parameter Meters

• Horiba U-52

• YSI 556

• YSI Pro Plus

• YSI ProDSS

• Hanna HI98194

• Aquaread AP 700

• Aquaread AP 800 (Also includes turbidity)

Turbidity

• Hanna HI98703

• Geotech Turbidity Meter

• Lamotte 2020t

• Lamotte 2020we

Thermometer

• NIST Certified Thermometer

5
LaMotte 2020we YSI ProPlus Horiba U-52

GROUND WATER SAMPLING SUPPLIES & PUMPS

Ground Water Sampling Supplies Available

• Tubing - Variety of types cut at custom lengths

• Bailers - Poly Weighted, PVC Weighted, etc.

• Filters & Accessories

– Micron Filters

– Poly Transfer Vessel System

– Well Plugs

– Vapor Extraction Plugs

• Well Devlopment

– Qwater Well Developers

– Foot Valves

• Disposable Gloves

• DECON-IT® Decontamination Agent

Sampling Pumps

• Proactive

– Water Spout®

– Typhoon®

– Monsoon®

– Hurricane® and more...

• Geotech SS Geosub 2

• Grundfos Redi-Flo 2”, 3”, 4”

Bladder Pumps

• Spectra Bladder Pump Sil

• Geotech Portable Bladder Pump

• QED Sample Pro and more...

Peristaltic Pumps

• Spectra Field Pro III

• Geotech Geopump™ II

HDPE Tubing

Well Plug

6
Geopump™ II Field Pro III Spectra Bladder Pump Sil Geotech SS Geosub 2
7 FEI PHILADELPHIA Customer Service Representative Ed Bursich EBursich.pa@fieldenvironmental.com 866-648-8607 Contact Ed Bursich at our Philadelphia branch for information on our New Jersey lab certified water quality rental equipment.
Winkler Method - verification method used for dissolved oxygen process

EQUIPMENT RENTAL

• Fairest rates in the industry

• Flexible rental terms, real-time rentals

• Rental period STARTS the day after you receive the equipment (except for morning deliveries

Rental Rates Equipment Support

• Rental period ENDS the business day before FEI receives the equipment; for LOCAL PICKUP, the rental period ends the day you call

Delivery

• FREE local delivery and pick-up of equipment

• Equipment arrives the day before rental starts

• Items shipped worldwide via FedEx or UPS

• No calibration or maintenance fees

• Instruments serviced and calibrated to manufacturers’ specifications

• 24/7 technical support

• Cleaning, calibrating, and servicing the industry’s most popular equipment

Are you in the GREEN ZONE?

Next day ground delivery available in certain regions

Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.